Settings
Connect the power supply and the load, you can supply to the controller,
Is displayed as a measured temperature,
Press the SET button, the display flashes the temperature,
Press -&+ to set the desired temperature,
After setting press SET to confirm the return,
The controller automatically performs the relay by setting off!
Long press SET 5 seconds to enter the main menu settings,
Press the + – toggle P0 … P8 long press SET,
10 seconds of no key activity confirmed their return to the controller.
Code Description Setting range Factory setting
P0 Cooling /Heating C/H C
P1 Hysteresis setting 0.5-15 2
P2 Highest setting upper limit 110 110
P3 Lowest setting upper limit -50 -50
P4 Temperature correction -7-7℃ 0
P5 Delay start time 0-10 Minutes 0
P6 High-temperature alarm 0-110℃ OFF
Lights, LED status descriptions:
Indicator: Off The relay is switched off, Always indicate the relay is closed.
Display:
LL is the sensor open.
HH is out of range, the thermostat will be forced to close the relay.
— as high-temperature protection.
Note: Relay output interface is a switch when it working, these two ports are connected. If not work, these two ports are not connected.