$82.6
Product Description
In stock (can be backordered)
Included:
Settings:
Power emperor window shows the current real-time temperature
Ent: Enter, according to a determined set value, press switch can be realized.
SET: Setting key, press once to enter the main menu (F1-F5)
“+” Plus key: increase the value display panel
“-” Minus key: decrease the value of the panel display
Internal Setting Description:
Press the SET panel display F1-F5, can be set for each parameter by key operation
F1: Set the desired temperature
F2: Setting the operating mode H = Heating, C = [refrigeration] This step is very important.
F3: Hysteresis setting, which is the number of degrees down to work again.
F4: Temperature correction, real-time display value = value + correction
F5: High-temperature alarm, reaches this temperature the thermostat will prompt alarm
Instructions
Set the target temperature value F1 (stop temperature)
Setting the F2 pattern, H is heating, C is Cooling
Setting back the difference, (the number of stop-start to fall again)
Display:
LLL / HHH: Sensor fault or sensor not connected
Mode / Cooling: lights shows that the current mode is a cooling mode
Mode/heating: Lit describes the current mode is a heating mode
Start: Lit explained that it had started the output relay is closed
Note: Relay output interface is a switch when it working, these two ports are connected. If not work, these two ports are not connected.